基于配电网故障D 型行波的改进型检测定位方法

黄守 华*, 张 浩, 孙 晓燕, 杜 轶轩
国网安徽省电力有限公司黄山分公司

摘要


传统的配电网故障定位方法在复杂性方面存在一定的缺陷,特别是故障发生在支线上。本研究提出了一种基于D 型行波的故障定位新方法。该方法选择初始行波首先到达的测量点作为参考测量点,并计算出多个故障点之间接收到故障行波信号到参考测量点的距离。然后,选择多个故障点到参考测量点之间的最大距离作为最终故障点的位置。ATP 仿真软件和MATLAB 软件的仿真结果表明,该方法可以在很短的时间内快速而准确地定位故障。与现有算法相比,该方法无论故障是发生在干线还是支线上都是一致的,从而提高了配电网行波故障定位的准确性和可靠性。

关键词


配电网;故障定位;D 型行波

全文:

PDF


参考


[1] Ji Tao,Sun Tong-jing,Xue Yong-duan,etal.Current status and development of fault location technique for distribution network[J].Relay,2005,33(24):32-37.

[2] Sang Zai-zhong,Pan Zhen-cun,Ding Lei,etal.The Principle and Application of “S Injection Method” for Faulty Line Selection[J].China Power,1997,30(6):44-45,62.

[3] Zhang Hui-fen,Pan Zhen-cun,Sang Zai-zhong.Injecting Current Based Method For Fault Location in Neutral Isolated Power System[J].Automation of Electric Power System,2004,28(3):64-66.

[4] Qi Zheng .Research on Technology of Line Detection and Fault Location for Single-phrase-to-earth Fault in Neutral Point Non-effectively Grounded Systems[D].Beijing:North China Electric Power University,2005.

[5] Xu Ru-jun ,Yan Feng .Location methods of single-phrase earth fault about 10kV distribution network[C].Information technology and Application meeting,2009.

[6] Dai Guang-wu.Study on Fault Area Location and Isolation of Distribution Network[D].Nanjing:Nanjing University of Science&Technology,2009.

[7] Wang Lin-chuan,Li Qing-xin,Liu Xin-quan,etal.Distribution network fault location based on the improved ant colony algorithm[J].Power System Protection and Control,2008,36(22):29-33,53.

[8] Xu Rong-ming.An Automatic Location System of Distribution Line Fault Based on Fault Indicator[J].Electrical Equipment,2005,6(10):66-67.

[9] NouriH,Chun Wang,Davies T.An accurate fault location technique for distribution lines with tapped loads using wavelet transform[C].Power Tech Proceedings 2001 IEEE Porto,Volume3,10 ~ 13 Sept.2001 Page(s):4pp.vol.3.

[10] DWP Thomas,C Christopoulos,et al.Single and double ended travelling-wave fault location on a MV system[C].Development in Power System Protection,2004.Eighth IEE International Conference,Volume 1,5-8 April 2004 Page(s):200-203 vol.1.

[11] Lin Jing-dong,Cao Chang-xiu,Zhang Bang-li,etal.Fault Section Diagnosis Algorithm of Distribution Networks Based on Topology Identification[J].Journal of Chongqing University,2001,24(5):51-54.

[12] Xie Yan-fei.Study on Improved Matrix Algorithm for Fault Location in Power Distribution Network[J].Journal of Electric Power,2011,26(3):199-201.

[13] Cheng Yan,Song Li-jun,Wang Wen,etal.Systematic Research and Relization of Fault Location of 35kV Lines[J].Relay,2007,35(8):16-20.

[14] Fernado H. Magnago,Ali Abur.Fault Location Using Wavelets[J].IEEE Trans on Power Deilvery,1998,13(4):1475-1480.

[15] Dong Xinzhou,He Jiali,Ge Yaozhong.Application of Wavelet Transform in Detection of Fault Travelling Waves[J].Relay,1998,26(5):1-4.




DOI: http://dx.doi.org/10.18686/dljsyj.v2i3.26624

Refbacks

  • 当前没有refback。